– 38 –
FUNCTION
Set vertical tab positions
CODE
<ESC> “B” n1 n2...nk <0>
(1B)
H (42)H n1 n2...nk (00)H
DEFINITION RANGE
1 n1 < n2 < n3 <....< nk 255, 1 k 16
OUTLINE
Cancels all current vertical tab positions and sets new vertical
tab positions at lines n1, n2, etc., where n1, n2, etc. are
numbers between 1 and 255. A maximum of 16 vertical tab
positions can be set. Tab positions must be specified in
ascending order; any violation of ascending order terminates
the tab position list. Standard termination is by the <0>
control code. Vertical tab positions are set in terms of the
current line spacing and do not move if the line spacing is
changed later.
NOTE
If a tab set position <nk> is equivalent or smaller than
<nk–1> just preceding the tab set position, setting of vertical
tab is assumed as complete.
FUNCTION
Execute vertical tab
CODE
<VT>
(0B)
H
OUTLINE
Feeds the paper to the next vertical tab set position.
When a vertical tab is not set, line feed is not performed. If the
current line is at or below the last vertical tab set position, the
paper feeds to the top of the next page.
FUNCTION
Set bottom margin
CODE
<ESC> “N” n
(1B)H (4E)H n
DEFINITION RANGE
0 n 255 (Default n = 0)
OUTLINE
Sets bottom margin to n lines.
Page length
Feeds the paper
automatically.
Bottom margin of n lines.